Анализатор элементов
Анализатор элементов
Атомно-абсорбционный спектрофотометр | Анализатор ртути |
Автоматический робот для разложения графита
ГЛАВНАЯ>>Анализатор элементов>>ICP spectrometer
ИСП-спектрометр
This full-spectrum direct-reading ICP-OES spectrometer is built to excel in demanding daily operations. Its superior stability and user-centric design ensure effortless operation from day one.
Robust Core Components:
Features a reliable solid-state RF power supply, a constant-temperature 2D optical system for unwavering accuracy, and a research-grade cooled CCD detector.
Intelligent Spectral Correction:
Incorporates advanced, locally developed correction technology to enhance flexibility and ensure exceptional analytical reliability.
Minimal Maintenance:
Designed for operational simplicity, it reduces routine upkeep and integrates seamlessly into high-throughput environments, realizing the ideal of a compact, smart, and conventional spectrometer.
Приложение
This full-spectrum direct-reading ICP-OES spectrometer is designed for diverse analytical challenges across numerous industries. It is extensively applied in fields including environmental protection, food safety, geology & mining, metallurgy & non-ferrous metals, rare earths, chemical engineering, clinical medicine, petroleum products, semiconductors, and agricultural research. Capable of determining major, minor, and trace element contents in various substances, the instrument performs qualitative, semi-quantitative, and precise quantitative analyses with an impressive detection limit reaching the parts-per-billion (ppb) level.
ДОСТУПНЫЕ МОДЕЛИ
Full-spectrum Direct-reading Inductively Coupled Plasma Optical Emission Spectrometer
Bidirectional Observation Full-spectrum Direct-reading Inductively Coupled Plasma Optical Emission Spectrometer
Подробная техническая спецификация
TECHNICAL PARAMETER
High-frequency generator
Circuit type: | All solid-state RF power supply Input power supply: 220V, 30A | ||
Operating Frequency: | 27.12 MHz | Frequency Stability: | <0.01% |
Output power: | 800~1500W | Output power stability: | ≤0.01% |
Electromagnetic field leakage radiation intensity: | At a distance of 30cm from the chassis, electric field: E < 10V/m; Magnetic field: H < 0.2A/m | ||
Gas control flow rate size: | Plasma gas flow meter: (1 ~ 20) L/min Auxiliary gas flow meter:(0.05 ~ 1.0) L/min | ||
Cooling water: | The water temperature range is 20°C~25°C, the flow rate is greater than 7L/min, the water pressure is greater than 0.1MPa, and the cooling water resistance is greater than 1 MΩ | ||
Polychromator
Light path: | Middle step grating+prism cross dispersion type | Focal length: | 440mm |
Grating specifications: | Echelle grating | Wavelength range: | 175nm ~870nm |
Nitrogen purge: | High speed blowing 6L/min, normal blowing 2L/min | ||
CCD
Detection wavelength range: | 165nm ~ 900nm | Quantum efficiency: | >30% at 200nm |
Refrigeration temperature: | -45°C | Nitrogen purging flow rate: | 3L/min |
Technical indicators of the entire machine
Wavelength range: | 175nm~900nm | Repeatability: | Relative standard deviation RSD < 1.5% |
Stability: | Relative standard deviation RSD < 1.0% | ||
Optional configurations to meet different applications
Various accessories can be used to increase the automation level and improve the performance of the instrument,thus meeting different application requirements.
Automatic sampler
The characteristics include fast injection speed, multiple sample cup positions, high accuracy, long lifespan, and low operating noise. The three-axis motor is divided and coordinated, and the completion time of one sampling is less than 30 seconds.
Simultaneous hydride generation device
The simultaneous hydride generation device can simultaneously analyze hydrogenated elements and other elements without the need to replace the injection device. It can effectively enhance the sensitivity of elements such as mercury, arsenic, lead, tin, antimony,germanium, etc.
Refrigeration system
Parameter description:
- Fast cooling, independent power supply, reaching stable temperatureonly takes 10 minutes.
- When the temperature in the fog chamber reaches -25 °C.
ensure optimal conditions for analyzing oil samples for volatile samples.
- Precise temperature control improves the stability of the analyze.
Meet different injection requirements
Multiple types of atomizers, mist chambers, and torch tubes are available, which can meet different injection requirements such as organic, high salt, high sensitivity, and HF acid resistance,making it easy to replace and maintain.
▪FOB
▪CIF
▪Упаковка: Деревянный ящик