ICP-MS spectrometer

 

 

ICP-MS provides elemental analysis solutions in the fields of environment, food, pharmaceuticals, materials, and more.

Application

AVAILABLE MODELS

PlasmaMS 300 ICP-MS spectrometer
PlasmaMS 400 ICP-MS spectrometer

AVAILABLE MODELS

Detailed Technical Specification

Quadrupole Analyzer

  • High throughput quadrupole (analysis mass range: 1-265amu) can totally meet the demands for high resolution (< 0.8 amu) element analysis  
  • Through the application of world’s leading quadrupole RF power supply technology and DDS (Direct Digital Frequency Synthesis) technology, it can realize automatic frequency matching and bring about remarkable stability and maintainability.

Vacuum System

High performance turbo molecular pump and external mechanical pump can quickly realize the high vacuum of instrument and ensure the signal sensitivity. Fully automatic vacuum control system can ensure the long-term stability of instrument operation.

27.12 MHz Inductively Coupled Plasma RF generator

By using the solid-state RF generator with extremely high power stability and good shielding design, PlasmaMS 300 can ensure the stability of ion source and signal. In addition, the adoption of precisely-controlled three-dimensional platform realizes the automatic positioning and calibration of the torch.

Flexible switching of sampling introduction methods

The ports for coupling with such external sampling devices as laser ablation and liquid chromatography are provided, the assembly space for semiconductor cooling device is reserved and HF acid resistant sampling system (Optional Accessories) can be switched.

Collision cell system

The collision cell, operated by high-performance mass flow controller and gas control software, can quickly complete the helium collision model and effectively eliminate the interference.

Excellent reliability and stability

With sturdy and durable RF power supply, vacuum system with emergency protection and the automatic control system, and intelligent one-key operation for completing analysis and configuration, PlasmaMS 300 eliminated the human disturbance, guarantee the consistency and excellent repeatability of the instrument.

Excellent Analysis Capabilities

The solid-state ICP source with excellent matching function can effectively limit the ion diffusion during ionization process and guarantee the focusing capability and highly pass rate of ion. The ion optical system with deflection can ensure the optimal ion focusing effect, effectively reduce the background noise and thus improve the signal-to-noise ratio.

Powerful coupling technology

It can conveniently couple with laser ablation sampling system (LA) and liquid chromatography (LC). In combination with LA system, PlasmaMS 300 can realize the solid-state direct sampling and simultaneously determine the contents of major, minor and trace elements in aerosol samples. The coupled system avoids complicated sample preparation process, improves the sampling and testing efficiency, and expands the detection capability of PlasmaMS 300. In combination with LC, it can conduct the speciation analysis of elements in organic substance, further expand the detection capability and efficiency of PlasmaMS 300 and provide more comprehensive application solutions.

User-friendly Operation Process

The intuitive and convenient “One-click” parameter settings can improve the work efficiency of users, also provide user-defined report format according to customer requests and supply QC function and LIMS interface.

Convenient Maintenance

The easy-to-disassemble and clean cones and deflection ion optical system can reduce ion deposition and extend the maintenance cycle of instrument. Durable solid-state ICP source can ensure trouble-free use for a long time.

  • 27.12MHz high-efficiency and stable all solid state RF generator.
  • The high-speed dynamic collision reaction pool maximizes the elimination of multi atomic ion interference.
  • Self developed DDS frequency conversion technology, automatic frequency fast matching and tuning, ensuring the stability of the quality axis.
  • Simple and easy-to-use software system that allows for one click setting of work status, improving testing efficiency.
  • Rich interfaces that can be used in conjunction with IPLC, LA, etc. to achieve morphological analysis, direct solid injection analysis, etc.