Oil Cooler
An oil cooler is a cooling device used in the industrial field, primarily for cooling the oil of various mechanical equipment to maintain its operating temperature within a reliable range.
Cooling capacity: 2500-200000 Kcal/h
Temperature control range: 25-45℃
Refrigerant:R22/R407C/R410a or others
Application Range:
- Machining centers, lathes, grinding machines, broaching machines, woodworking machinery, textile machinery
- Hydraulic system, lubrication system, hydrostatic system
- High-speed spindle
- Gearbox, Transmission
AVAILABLE MODELS
YLD A
This model does not come equipped with a circulating oil pump; instead, it is connected in series to the oil supply and return pipelines of the hydraulic and lubrication systems. The maximum operating pressure for this product series is less than 2 MPa.
YLD PA
This model is equipped with a built-in circulating oil pump that circulates oil in the static pressure and hydraulic system tanks; it automatically activates cooling or heating functions based on the set temperature, thereby maintaining the oil temperature within a constant range.
YLD PAX
This model is equipped with a built-in circulating oil pump and an oil tank providing oil at a constant temperature to a closed-loop system (e.g., machining center spindle/electric spindle).
Detailed Technical Specification
- Calculate the Heat Value Based on the Temperature Difference Between the Cooling Water (oil) Inlet and Outlet Temperatures.
Q=SH × De × F × DT / 60
Q:Heat output / KW
SH:The specific heat capacity of hot water is 4.2 kJ/kg*°C (4.2 kJ per kilogram per degree Celsius);
the specific heat capacity of oil is 1.97 kJ/kg*°C (1.97 kJ per kilogram per degree Celsius).
DE:The specific gravity of water is 1 kg/L; the specific gravity of oil is 0.88 kg/L.
F:Flow rate LPM (L/min)
DT:Cooling water (oil) inlet–outlet temperature difference (outlet temperature – inlet temperature) Note:“/60” is used to convert flow rate from liters per minute to liters per second; 1 kW= 1 kJ/s;
Example 1: Cooling water inlet temperature: 15 °C; cooling water outlet temperature: 20 °C; flow rate: 20 L/min
Heat output Q = 4.2 × 1 × 20 × (20 – 15) / 60 = 7 kW
When selecting the cooling capacity for a cooler, you may increase it by 20%–50%.
Example 2: Cooling oil inlet temperature: 18 °C; cooling oil outlet temperature: 26 °C; flow rate: 15 L/ min
Heat output Q = 1.97 × 0.88 × 15 × (26 – 18) / 60 = 2.6 kW
When selecting the cooling capacity for a chiller unit, you may increase it by 20%–50%.
- Estimation Based on Equipment Power and Heat Generation
- A.For spindle cooling applications, the required cooling capacity of the refrigeration unit can be estimated as 30% of the spindle motor’s power rating.
Example: 15 kW motor; optional refrigeration units with a cooling capacity of 4.5 kW or 5.8 kW are available;
- The injection molding machine can be calculated based on a cooling capacity of 0.6 kW per US gallon or a refrigeration capacity of 3 kW per80 tons;
III. Calculate the Heat Output Based on the Temperature Rise of the Water (or Oil) Tank.
Q=SH × De × V × DT / 60
Q:Heat output KW
SH:The specific heat capacity of hot water is 4.2 kJ/kg ·°C (4.2 kilojoules per kilogram per degree Celsius);
the specific heat capacity of oil is 1.97 kJ/kg ·°C (1.97 kilojoules per kilogram per degree Celsius).
DE:The specific gravity of water is 1 kg/L ; the specific gravity of oil is 0.88 kg/L.
V:Water capacity L (liters) refers to the total water capacity within the water tank and piping system. DT:Maximum temperature rise of water (oil) within one minute
Note:”/60″ is used to convert a temperature rise from degrees Celsius per minute to degrees Celsius per second; 1 kW= 1 kJ/s;
Note: During measurement, the temperature of the water (oil) tank should be slightly lower than the ambient temperature; additionally, the equipment should be operating under its maximum load.
Example: Water tank capacity – 3000 L; Maximum water flow rate – 0.6 °C/min
Heat output Q = 4.2 × 1 × 3000 × 0.6 / 60 = 126 kW
When selecting the cooling capacity for a chiller, you may increase it by 20%–50%;
Supplementary Specification:
- 1.The cooling capacity of the chiller varies depending on the ambient temperature and the outlet water temperature;
- 2.The actual heat generation of the equipment may also vary depending on factors such as the work pieces, molds, and parameters;
- 3.After the chiller is activated, the temperature drops; as a result, the temperatures of the connecting pipelines, water tank, oil tank, molds, main spindle, and equipment surfaces will be lower than the ambient temperature, leading to heat absorption and an increased load;
- 4.In practical industrial cooling applications, it is often not feasible to accurately apply the aforementioned methods for calculation; in such cases, estimation must be made using empirical data or by drawing analogies with similar equipment.
- 5.Any calculation method may introduce deviations, leading to the selection of a refrigeration unit that is either too large or too small; therefore, the above method should be used only as a reference.
Specifications and Technical Parameters | ||||||
Model |
| YLD25 | YLD35 | YLD45 | YLD60 | |
Refrigerating capacity | [Kcal/h] | 2500 | 3500 | 4500 | 6000 | |
Temperature control range |
| Adjustable range: 25–45°C | ||||
Service condition | Environmental Requirements | [℃] | Temperature: 5–43°C; Good ventilation; No dust or corrosive aerosols; No exposure to sunlight or rain; No thermal radiation; No vibration | |||
Oil temperature | [℃] | 15~50 | ||||
General supply |
| 3PH/AC380V±10%/50Hz | ||||
Input power without pump | [Kw] | 1.0 | 1.5 | 1.9 | 3 | |
Input power with pump | [Kw] | 1.4 | 2.2 | 2.7 | 4 | |
Rated current with pump | [A] | 6 | 8 | 11 | 7 | |
Oil pump power | [Kw] | 0.4 | 0.75 | 0.75 | 1.1 | |
Oil pump flow rate | [L/min] | 14 | 20 | 25 | 40 | |
Flow ratewithout oil pump | [L/min] | -10%~+50% | ||||
Piping specifications | [internal thread] | G¹/2“ | G3/4“ | G3/4“ | G1 “ | |
Outer dimension | Widith | [mm] | 500 | 550 | 550 | 640 |
Thickness | [mm] | 500 | 600 | 600 | 660 | |
Height | [mm] | 900 | 1100 | 1100 | 110 | |
Weight | [Kg] | 95 | 115 | 130 | 150 | |
Cryogen | R22/R407C/R410a or others | |||||
Security guard | Refrigerant high-and low-pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase reversal/overvoltage/undervoltage protection | |||||
YLD25-60 Dimensional Drawing | |||||||||
Model | A | B | C | D | E | F | G | H | I |
YLD25 | 500 | 500 | 900 | 460 | 355 | 420 | 100 | G¹/2“ | G¹/2“ |
YLD35 | 550 | 600 | 1100 | 510 | 455 | 400 | 120 | G3/4“ | G3/4“ |
YLD45 | 550 | 600 | 1100 | 510 | 455 | 400 | 120 | G³/4 “ | G³/4 “ |
YLD60 | 640 | 660 | 1100 | 600 | 515 | 500 | 120 | G1 “ | G1″ |
Remarks:
◆This product series includes three models for selection: the model without pump or fuel tank, the model with pump but without fuel tank, and the model with both pump and fuel tank.
◆During installation, maintain a clearance of 80 cm at the air intake and a clearance of 200 cm at the hot air exhaust outlet.
◆The above cooling capacity was measured under conditions of an oil temperature of 35 °C and an ambient temperature of 35 °C; the cooling capacity decreases as the ambient temperature rises and the oil temperature falls.
◆YLD25/35/45 – Only three-phase, five-wire system.
◆Our products are continuously being improved; the specific structural dimensions may differ from the parameters listed above.
Specifications and Technical Parameters | ||||
Model |
| YLD80 | YLD120 | |
Refrigerating capacity | [Kcal/h] | 8000 | 12000 | |
Temperature control range |
| Adjustable range: 25–45°C | ||
Service condition | Environmental Requirements | [℃] | Temperature: 5–43°C; Good ventilation; No dust or corrosive aerosols; No exposure to sunlight or rain; No thermal radiation; No vibration | |
Oil temperature | [℃] | 15-50 | ||
General supply |
| 3PH/AC380V±10%/50Hz | ||
Input power without pump | [Kw] | 3.5 | 4.5 | |
Input power with pump | [Kw] | 5.0 | 6.0 | |
Rated current with pump | [A] | 9 | 11 | |
Oil pump power | [Kw] | 1.5 | 1.5 | |
Oil pump flow rate | [L/min] | 50 | 50 | |
Flow ratewithout oil pump | [L/min] | -10%~+50% | ||
Piping specifications | [internal thread] | G1 ” | G1 ” | |
Outer dimension | Widith | [mm] | 700 | 700 |
Thickness | [mm] | 800 | 800 | |
Height | [mm] | 1240 | 1240 | |
Weight | [Kg] | 150 | 180 | |
Cryogen | R22/R407C/R410a or others | |||
Security guard | Refrigerant high-and low-pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase reversal/overvoltage/undervoltage protection | |||
YLD80- 120 Dimensional Drawing | ||||||||||
Model | A | B | C | D | E | F | G | H | I | J |
YLD80 | 700 | 800 | 1240 | 660 | 655 | 120 | 120 | 410 | G1 ” | G1 ” |
YLD120 | 700 | 800 | 1240 | 660 | 655 | 120 | 120 | 410 | G1 ” | G1 ” |
Remarks:
◆This product series includes three models for selection: the model without pump or fuel tank, the model with pump but without fuel tank, and the model with both pump and fuel tank.
◆During installation, a space of 80 cm must be reserved at the air intake, and a space of 200 cm must be reserved at the hot air exhaust outlet.
◆The above cooling capacity was measured under conditions of an oil temperature of 35 °C and an ambient temperature of 35 °C; the cooling capacity decreases slightly as the ambient temperature rises and the oil temperature falls.
◆Our products are continuously being improved; the specific structural dimensions may differ from the parameters listed above.
Specifications and Technical Parameters | ||||||
Model |
| YLD150 | YLD180 | YLD240 | YLD300 | |
Refrigerating capacity | [Kcal/h] | 15000 | 18000 | 24000 | 30000 | |
Temperature control range |
| Adjustable range: 25-45°C | ||||
Service condition | Environmental Requirements | [℃] | Temperature: 5–43°C; Good ventilation; No dust or corrosive aerosols; No exposure to sunlight or rain; No thermal radiation; No vibration | |||
Oil temperature | [℃] | 15-50 | ||||
General supply |
| 3PH/AC380V±10%/50Hz | ||||
Input power without pump | [Kw] | 6.0 | 7.0 | 10 | 12 | |
Input power with pump | [Kw] | 85.5 | 9.5 | 13 | 15 | |
Rated current with pump | [A] | 16 | 18 | 5 | 28 | |
Oil pump power | [Kw] | 2.2 | 2.2 | 3 | 3 | |
Oil pump flow rate | [L/min] | 63 | 80 | 100 | 126 | |
Flow ratewithout oil pump | [L/min] | -10%~+50% | ||||
Piping specifications | [internal thread] | G1¹/4“ | G1¹/4“ | G1¹/2“ | G1¹/2“ | |
Outer dimension | Widith | [mm] | 70 | 700 | 800 | 800 |
Thickness | [mm] | 1100 | 1100 | 1300 | 1300 | |
Height | [mm] | 1290 | 1390 | 1500 | 1500 | |
Weight | [Kg] | 240 | 300 | 380 | 430 | |
Cryogen | R22/R407C/R410a or others | |||||
Security guard | Refrigerant high-and low-pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase reversal/overvoltage/undervoltage protection | |||||
YLD150–300 Dimensional Drawing | ||||||||||
Model | A | B | C | D | E | F | G | H | I | J |
YLD150 | 700 | 1100 | 1280 | 660 | 955 | 120 | 390 | 170 | G1¹/4″ | G1¹/4″ |
YLD180 | 700 | 1100 | 1380 | 660 | 955 | 120 | 390 | 170 | G1¹/4″ | G1¹/4″ |
YLD240 | 800 | 1300 | 1500 | 760 | 1155 | 120 | 410 | 120 | G1¹/2″ | G1¹/2″ |
YLD300 | 800 | 1300 | 1500 | 760 | 1155 | 120 | 410 | 120 | G1¹/2″ | G1¹/2″ |
Remarks:
◆This product series includes three models for selection: the model without pump or fuel tank, the model with pump but without fuel tank, and the model with both pump and fuel tank.
◆During installation, a minimum space of 80 cm should be reserved at the air intake, and a minimum space of 200 cm should be reserved at the hot air exhaust outlet.
◆The above cooling capacity was measured under conditions of an oil temperature of 35 °C and an ambient temperature of 35 °C; the cooling capacity decreases as the ambient temperature increases and the oil temperature decreases.
◆Our products are continuously being improved; the specific structural dimensions may differ from the parameters listed above
Specifications and Technical Parameters
Model
YLD400
YLD500
YLD600
YLD800
YLD1000
YLD1200
Refrigerating capacity
[Kcal/h]
40000
50000
60000
80000
100000
120000
Temperature control range
Adjustable range: 25–45°C
Service
condition
Environmental
Requirements
[℃]
Temperature: 5–43°C; Good ventilation; No dust or corrosive aerosols; No exposure to sunlight or rain; No thermal radiation; No vibration
Oil temperature
[℃]
15~50
General supply
3PH/AC380V±10%/50Hz
Input power without pump
[Kw]
15
19
23
30
43
49
Input power with pump
[Kw]
19
25
28
38
54
60
Rated current with pump
[A]
36
48
55
75
105
115
Oil pump power
[Kw]
4
5.5
5.5
7.5
11
11
Oil pump flow rate
[L/min]
160
200
263
315
400
526
Flow ratewithout oil pump
[L/min]
-10%~+50%
Piping specifications
[internal thread]
DN65
DN80
DN80
DN100
DN125
DN125
Outer
dimension
Widith
[mm]
800
900
1000
1000
1100
1100
Thickness
[mm]
1500
1700
1900
2000
2200
2800
Height
[mm]
1800
1900
2000
2050
2250
2150
Weight
[Kg]
600
700
800
1000
1200
1600
Refrigerant
R22/R407C/R410a or others
Security guard
Refrigerant high-and low-pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase reversal/overvoltage/undervoltage protection
YLD400 – 1200 Dimensional Drawing
Model
A
B
C
D
E
F
G
H
I
J
YLD400
1750
800
1500
760
1100
250
200
280
DN65
DN65
YLD500
1900
900
1700
860
1300
250
200
350
DN80
DN80
YLD600
1900
1000
1900
960
1500
250
200
350
DN80
DN80
YLD800
2050
1000
2000
960
1600
250
200
350
DN100
DN100
YLD1000
2250
1100
2200
1060
1700
250
230
380
DN125
DN125
YLD1200
2150
1100
2800
1060
2300
250
230
380
DN125
DN125
Remarks:
◆During installation, a space of approximately 80 cm should be reserved around the perimeter; at the hot air exhaust outlet, a space of approximately 200 cm should be reserved.
◆The above cooling capacity was measured under conditions of an oil temperature of 35°C and an ambient temperature of 35 °C; the cooling capacity decreases as the ambient temperature rises and the oil temperature falls.
◆Our products are continuously being improved; the specific structural dimensions may differ from the parameters listed above.
Specifications and Technical Parameters | ||||
Model |
| YLD1600 | YLD2000 | |
Refrigerating capacity | [Kcal/h] | 160000 | 200000 | |
Temperature control range |
| 25~45 | 25~45 | |
Service condition | Environmental Requirements | [℃] | 0~43 | 0~43 |
Oil temperature | [℃] | 15~50 | 15~50 | |
General supply |
| 3PH/AC380V±10%/50Hz | ||
Input power without pump | [Kw] | 60 | 85 | |
Input power with pump | [Kw] | 71 | 100 | |
Rated current with pump | [A] | 140 | 195 | |
Oil pump power | [Kw] | 11 | 15 | |
Oil pump flow rate | [L/min] | 600 | 800 | |
Flow ratewithout oil pump | [L/min] | -10~+50% | ||
Piping specifications | [flange] | DN150 | DN200 | |
Other | Weight | [Kg] | 1900 | 2300 |
Refrigerant | R22/R407C/R410a or others | |||
Protection | Refrigerant high/low pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase sequence protection; excessive oil temperature protection | |||
Remarks:
◆During installation, a space of approximately 100 cm should be reserved around the perimeter; at the hot air exhaust outlet, a space of approximately 300 cm should be reserved.
◆The above cooling capacity was measured under conditions of an oil temperature of 35°C and an ambient temperature of 35 °C; the cooling capacity decreases as the ambient temperature rises and the oil temperature falls.
◆Our products are continuously being improved; the specific structural dimensions may differ from the parameters listed above.
Application range:
- Primarily used for temperature control in aqueous or oily solutions containing various impurities, such as cutting fluids.
- Temperature control for various corrosive liquids.
- For applications where the fuel tank and water tank need to be integrated into a single unit.
Note:
- When selecting, designing, or operating adrop-inoil-cooling unit, special attention must be paid to the compatibility between the oil tank dimensions, the liquid level height, and the unit itself; it must be ensured that the bottom coil of the oil-cooling unit is always fully submerged within the coolant tank and not exposed.
- When the oil cooler is in operation, it is essential to ensure that a sufficient liquid flow passes through the bottom evaporator coil. If this flow rate cannot be guaranteed, you may consider ourdrop-in oil cooler equipped with a stirring pump.
- The material of the bottom coil can be selected according to specific requirements – available in copper, stainless steel, or titanium tubes(unless otherwise specified, stainless steel tubes are typically used).
| Specifications and Technical Parameters | ||||||||||||
| Model | YLJ25 | YLJ35 | YLJ45 | YLJ60 | YLJ80 | YLJ120 | YLJ150 | YLJ180 | YLJ240 | YLJ300 | ||
| Refrigerating capacity | [Kcal/h] | 2500 | 3500 | 4500 | 6000 | 8000 | 12000 | 15000 | 18000 | 24000 | 30000 | |
| Rated power | [Kw] | 1 | 1.5 | 1.9 | 3 | 3.5 | 4.5 | 6 | 7 | 10 | 12 | |
| Rated current | [A] | 6 | 9 | 11 | 6 | 7 | 9 | 12 | 14 | 19 | 23 | |
| Flow rate through the coil | [L/min] | >14 | >20 | >25 | >40 | >50 | >50 | >60 | >80 | >100 | >120 | |
| Temperature control range | [℃] | 25-45 adjustable | ||||||||||
Service condition | Environmental Requirements | [℃] | 0-43 | |||||||||
| Oil/water temperature | [℃] | <50 | ||||||||||
| General supply | [V] | 3PH/AC380V ± 10%/50Hz (among which 25/35/45 types only have three-phase five wire system or single-phase 220V) | ||||||||||
| Refrigerant | R22/R407C/R410a or others | |||||||||||
| Protection | Refrigerant high/low pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase sequence protection; excessive oil temperature protection | |||||||||||
| Outer Dimensional | ||||||||||
| Model | A | B | C | D | E | F | G | H | I | J |
| YLJ25 | 580 | 500 | 500 | – | 400 | 400 | 100 | 380 | 460 | 355 |
| YLJ35 | 680 | 550 | 600 | – | 450 | 500 | 100 | 380 | 510 | 455 |
| YLJ45 | 680 | 550 | 600 | – | 450 | 500 | 100 | 380 | 510 | 455 |
| YLJ60 | 780 | 640 | 660 | – | 540 | 560 | 100 | 500 | 600 | 515 |
| YLJ80 | 610 | 700 | 800 | – | 600 | 700 | 150 | 500 | 660 | 655 |
| YLJ120 | 610 | 700 | 800 | – | 600 | 700 | 150 | 500 | 660 | 655 |
| YLJ150 | 620 | 700 | 1100 | – | 600 | 1000 | 150 | 500 | 660 | 955 |
| YLJ180 | 720 | 700 | 1100 | – | 600 | 1000 | 150 | 500 | 660 | 955 |
| YLJ240 | 850 | 800 | 1300 | – | 700 | 1200 | 200 | 600 | 760 | 1155 |
| YLJ300 | 850 | 800 | 1300 | – | 700 | 1200 | 200 | 600 | 760 | 1155 |
Remarks:
◆YLJ is suitable for cooling aqueous or oily fluids containing impurities, such as cutting fluids. The dimensions of the bottom cooling coil and the lower frame are adjusted according to the type of fluid being cooled (aqueous or oily).
However, variations may occur due to differences in the type of liquid or in the accompanying fuel tanks and liquid level heights; the dimensions E, F, G and H shall be determined through negotiation.
◆Our products are continuously being improved; therefore, the specific parameters and dimensions may differ from those listed in the table.