In industrial processing or manufacturing processes across sectors such as laser technology, mold manufacturing, chemical industry, and food processing, it is often necessary to cool water or water-soluble liquids to ensure processing accuracy and product quality. The SL series chiller developed by our company meet the diverse temperature   control requirements for water and water-soluble liquids in various industrial applications, making them particularly suitable for applications where high water temperature accuracy is critical.

 

Model Selection

SLD  80  P  A  X

X: Built-in water tank

□: Without water tank

A: Fixed-temperature type

P: Built-in water pump

□: Without pump

Nominal cooling capacity (x100 Kcal/h)

SLD:Standalone chiller

SLJ:Drop-in chiller

(SLJ specifications and parameters are the same as those of the YLJ series)

Feature and Function

Major components are imported branded products, safe and reliable;

The evaporator utilizes a high-efficiency 316L stainless steel plate heat exchanger, featuring high heat transfer efficiency, compact size, and excellent corrosion resistance;

The condenser is meticulously manufactured using US OAK heat exchanger processing equipment, ensuring high heat transfer efficiency;

Air-cooled cooling system – no cooling water or water tower required; easy installation;

Imported temperature controller with digital display – easy and convenient setup;

Equipped with an automatic fault alarm function that can output corresponding signals to enhance equipment operational safety;

High temperature control accuracy, with a maximum accuracy of ± 1 °C;

Comprehensive range of specifications and wide temperature control range – capable of meeting the temperature control requirements of various equipment;

Elegant appearance with surface powder coating treatment.

Applicable Equipment

Laser / Medical Device / Specialized Laser Cutting and Engraving Machine / CNC machine / CNC wire-cutting machine / Printing machine / Foaming machine / Injection molding machines / Various extrusion molding machine / Die-casting machine / Induction heating equipment / Power supply /Mold cooling / Other areas requiring cooling

Detailed Technical Specification

Specifications and Technical Parameters

Model

 

SLD25

SLD35

SLD45

SLD60

SLD80

SLD120

SLD150

SLD180

SLD240

Refrigerating capacity

[Kcal/h]

2500

3500

4500

6000

8000

12000

15000

18000

24000

Rated total power

[Kw]

1.5

2

2.5

3.5

4.2

5.2

7

8

11.5

Rated total current

[A]

7

8

10

7

8

10

13

15

22

Pump capacity

[L/min]

10

15

220

20

30

40

50

60

80

Pump power

[Kw]

0.55

0.55

0.55

0.55

0.75

0.75

1.1

1.1

1.5

Water inlet and outlet

 

G1/2’’

G1/2’’

G1/2’’

G3/4’’

G1’’

G1’’

G1-1/4’’

G1-1/4’’

G1-1/4’’

Pump head

[m]

30

30

30

30

30

30

30

30

30

 

External   dimensions   (without water tank)

Width

[mm]

500

550

550

640

700

700

700

700

800

Thickness

[mm]

500

600

600

660

800

800

1100

1100

1300

Height

[mm]

1000

1200

1200

1200

1340

1340

1400

1500

1600

External

dimensions

with  built-in water tank

Width

[mm]

550

550

550

700

700

700

700

700

800

Thickness

[mm]

600

600

600

800

800

800

1200

1200

1300

Height

[mm]

1300

1300

1300

1340

1340

1340

1400

1500

1620

Built-in water tank capacity

[L]

50

50

500

2110

2110

210

150

150

1185

Weight

[Kg]

1110

1130

140

1155

11770

1180

220

280

350

Temperature control range

[℃]

8-30

Service

condition

Environmental Requirements

[℃]

2-43

Initial water temperature

[℃]

2-45

Suitable cooling water

 

Purified water, distilled water, deionized water, and other non corrosive and impurity free water or aqueous solutions

General supply

[V]

3PH/AC380V ± 10%/50Hz (among which 25/35/45 types only have three-phase five wire system or single-phase 220V)

Cryogen

R22/R407C/R410a or others

Protection

Refrigerant high/low pressure protection; overload/short-circuit/timeout protection; power supply phase loss/phase sequence protection; excessive oil temperature protection

Remarks:

◆This unit is available in both tanked and tankless versions for selection.

◆The pump head, interface dimensions, and pump flow rate in the table may be customized according to the customer’s specific requirements.

◆During unit installation, ensure proper ventilation and that there are no obstructions around the  unit. In winter, take necessary precautions against freezing.

◆Our products are continuously being improved; as a result, specific technical specifications may change.

Specifications and Technical Parameters

Model

 

SLD300

SLD400

SLD500

SLD600

SLD800

SLD1000

SLD1200

SLD1600

SLD2000

Refrigerating capacity

[Kcal/h]

30000

40000

50000

60000

80000

100000

120000

160000

200000

Rated total power

[Kw]

13.5

16.5

21

25.5

33

47

53

64

90

Rated total current

[A]

25

31

40

48

63

90

102

122

175

Pump capacity

[L/min]

100

140

170

200

280

350

420

550

700

Pump power

[Kw]

1.5

1.5

2.2

2.4

3

4

4

4

5.5

Water inlet and outlet

 

G1-1/4″

G1-1/2″

G2″

G2″

G2″

DN65

DN65

DN80

DN100

Pump head

[m]

30

30

30

30

30

30

30

30

30

 

External   dimensions   (without water tank)

Width

[mm]

800

800

900

1000

1000

1100

1100

1500

1800

Thickness

[mm]

1300

1500

1700

1900

2000

2200

2800

2800

3500

Height

[mm]

1600

1920

2000

2100

2150

2350

2250

2320

2370

External

dimensions

with  built-in water tank

Width

[mm]

850

850

1000

1000

1100

1100

1100

1500

1800

Thickness

[mm]

1420

1420

1900

1900

2200

2200

2800

2800

3500

Height

[mm]

1700

1800

2000

2000

2250

2350

2350

2520

2520

Built-in water tank capacity

[L]

240

240

380

380

500

510

620

1000

1400

Weight

[Kg]

400

600

700

700

1000

1200

1600

1900

2300

Temperature control range

[℃]

8-30

Service

condition

Environmental Requirements

[℃]

2-43

Initial water temperature

[℃]

2-45

Suitable cooling water

 

Purified water, distilled water, deionized water, and other non corrosive and impurity free water or aqueous solutions

General supply

[V]

3-phase/AC 380 V ±10% / 50 Hz (Single-phase 220 V or three-phase five-wire power supply available in specifications: 25,35, or 45 V)

Cryogen

R22 can be used with R407C, R410a, or other refrigerants.

Protection

Refrigerant high-and low-pressure protection; overload/short-circuit/timeout protection; power phase loss/phase sequence protection; excessive oil temperature protection

Remarks:

◆This unit is equipped with a water tank (SLD□□PAX) and tank-free (SLD□□PA)available as an option.

◆The pump head, interface dimensions, and pump flow rate in the table may be customized according to the customer’s specific requirements.

◆During unit installation, ensure proper ventilation and that there are no obstructions around the unit. In winter, take necessary precautions against freezing.

◆Our products are continuously being improved; as a result, specific technical specifications may change.

Dimension

Model

A

B

C

D

E

F

G

H

I

SLD25PAX

550

600

1200

510

455

110

330

150

G1/2”

SLD35PAX

550

600

1200

510

455

110

330

150

G1/2”

SLD45PAX

550

600

1200

510

455

110

330

150

G1/2”

SLD60PAX

700

800

1240

660

655

120

380

150

G1”

SLD80PAX

700

800

1240

660

655

120

380

150

G1”

SLD120PAX

700

800

1240

660

655

120

380

150

G1”

Remarks:

◆The dimensions listed in the above table may vary depending on the user’s specific requirements; for example, differences in pump flow rate or pump head can affect the dimensions.

◆Our products are continuously being improved; the actual dimensions may differ from those listed in the table.

Dimension

Model

A

B

C

D

E

F

G

H

I

SLD150PAX

700

1200

1280

660

1055

120

380

200

G1-1/4”

SLD180PAX

700

1200

1380

660

1055

120

380

200

G1-1/4”

SLD240PAX

800

1300

1500

810

1020

120

420

150

G1-1/4”

SLD300PAX

850

1420

1600

810

1020

120

470

150

G1-1/4”

SLD400PAX

850

1420

1700

810

1020

120

470

150

G1-1/2”

SLD500PAX

1000

2000

1900

860

1300

800

480

150

G2”

SLD600PAX

1000

2000

1900

960

1600

800

480

150

G2”

SLD800PAX

1100

2200

2150

1060

1700

900

480

150

G2”

SLD1000PAX

1100

2200

2250

1060

1700

900

480

150

DN65

SLD1200PAX

1100

2400

2250

1060

1900

900

480

150

DN65

SLD1600PAX

1500

2800

2400

1460

2000

 

 

 

DN80

SLD2000PAX

1800

3500

2400

1760

3100

 

 

 

DN100

Remarks:

◆The dimensions listed in the above table may vary depending on the user’s specific requirements; for example, differences in pump flow rate or pump head can affect the dimensions.

◆Our products are continuously being improved; the actual dimensions may differ from those listed in the table.

▪FOB

▪CIF

▪Package: Wooden case

en_USEN